______________
Shift Activity report
__________________
1.) 4RS, calendar stop in running so check roll-04, drive side gap close up to -0.7 mm. Change roll-04 d/s servo valve Cable.
2.) 120MM filler extruder, head zone temperature increase so check RTD , cooling valve found ok. Inform to mechanical to clean strainer.
3.) 3R-02, calendar stop so check and found roll-01 drive fault f002, reset and start.
4.) 3R-01, feed mill not starting so check Elmeasure controller was in line and its relay was continuously hold due. Remove relay connection then ok.
5.) 10″HFE, CC Mill-02 hydraulic oil temperature high so check it’s continuous going in loading. Clean chuck value, pressure relief valve then ok.
6.) 3R-01, CC mill sheet feeder not working so check drive fault f004 reset and start.
Total men Power -11+03
Next shift engineer -Raju